Two states: hot and cold. Hot-state cleaning: before changing paste, while rollers and blade are still warm, use a doctor blade and copper scraper (never steel — it damages roller surfaces) to remove residue, then wipe with matching solvent. Cold-state cleaning: after shutdown, thoroughly clean oven interior, ducts, guide rollers, and paste piping; cured residue must be soaked with dedicated cleaner before removal — hard scraping will scratch rollers. Oven residue must be cleaned regularly — this is a primary fire hazard; recommend weekly with a log. Paste piping must be flushed after every paste change; fittings and filters are the blockage points. After cleaning, run empty to confirm temperature and airflow are restored before feeding.
How Runda handles this
Cleaning procedures are delivered with the machine: copper scraper for hot rollers (never steel), cold-state oven and duct cleaning, and piping/filter flush after every paste change. Weekly oven cleaning with a log is required for fire safety.