Three steps. (1) Evaporation: hourly fabric weight × (incoming moisture − finished moisture) = hourly water evaporation (kg/h). (2) Effective heat: evaporated water × latent heat (~2260 kJ/kg, including heating); actual heat consumption = effective heat / thermal efficiency (overall stenter thermal efficiency is typically 50–70%, including exhaust loss). (3) Fuel: actual heat ÷ fuel heat value (natural gas ~35.5 MJ/m³) = hourly gas consumption; electricity is calculated separately as installed power × load factor. Example: if 100 kg/h water evaporates, effective heat is ~226 MJ; at 60% efficiency, actual need is ~377 MJ, or ~10.6 m³/h natural gas. Use this formula with meter readings to calculate real per-ton energy and cost.
How Runda handles this
Energy formulas are delivered with the machine: evaporation = fabric weight × (incoming moisture − finished moisture), actual heat = effective heat / efficiency, then fuel conversion. You can calculate per-ton cost yourself and use it to verify supplier energy promises.