What Is the Maximum Temperature of a Stenter Machine?

Typical process temperature is 180–210°C; equipment design limit is usually 220–230°C, depending on heat source, shell material, and seal temperature rating. But how high you can actually run is often limited by fabric, not equipment: cotton, viscose, and wool tolerate far less heat than polyester — over-temperature causes yellowing, stiff hand, and strength loss. Polyester setting must follow the process curve; too high causes over-shrinkage or over-setting. So the "max temperature" number only states equipment capability, not what you can use. What really matters is cross-machine temperature uniformity and control accuracy (±1–2°C fluctuation) — these affect quality more than the ceiling number.

How Runda handles this

Equipment capability is one thing; what you can use is another. Our acceptance is based on cross-machine uniformity and control accuracy (fluctuation range), not the ceiling number — both are written into acceptance clauses.