Why Is Fabric Loose in the Middle and Tight at the Edges on a Stenter?

Check three directions. (1) Cross-machine temperature and airflow imbalance: center and edge temperatures differ, causing under- or over-shrinkage in the center while edges are pulled tight. Verify with a 9-point cross-machine temperature measurement, then check duct distribution and blocked nozzles. (2) Grip variation: clips or pins grip edges differently from the center, stretching edges forcibly. Check chain pin wear, pin spacing, and over-feed setting. (3) Incoming fabric: prior processes (dyeing or washing) already have edge-to-center variation; the stenter just amplifies it. Response order: first measure cross-machine temperature, then adjust over-feed and weft straightener, then trace back to prior-process fabric. Adjusting tension alone usually makes it worse because the root cause is temperature or incoming fabric.

How Runda handles this

For middle-loose edges-tight, we do a 9-point cross-machine temperature check before delivery to bring differential within process tolerance, and provide over-feed, weft straightener, and edge tracking. During commissioning, our technician is on site and hands over these parameters to you.

Related equipment

Related questions

Wuxi Runda Dye-Finishing Equipment Factory
Qianzhou, Wuxi, Jiangsu, China 214181
Tel: +86-510-83383369 | Email: rd@runda2008.com | www.runda2008.com