Four steps. Step 1: Measure — use a multi-point thermometer (or fabric-surface measurement) at left, center, right minimum; ideally 9 points across, to confirm the actual deviation — do not rely on feel. Step 2: Check airflow — uneven duct distribution, blocked nozzles, or insufficient fan volume are the most common causes. Clean nozzles, adjust dampers, check fan belts and speed. Step 3: Check heating and sensors — local carbon buildup on heaters reduces heat transfer; thermocouple misplacement or failure makes readings falsely uniform. Calibrate and reposition to verify. Step 4: Check structure — shell leaks, damaged door seals, or heat loss at both width ends. After fixing, re-measure the same points; resolve means bringing differential within process tolerance (typically ±2°C).
How Runda handles this
The temperature-uneven troubleshooting checklist is provided: first 9-point cross-machine measurement, then duct distribution and nozzle blockage, then thermocouple position. Duct and nozzle layout drawings come with the machine so maintenance does not rely on guesswork.
Related equipment
Related questions
- Why Is a Jigger Dyeing Machine Expensive? Breaking Down the Cost Difference
- Why Can't Jigger Dyeing Machines Be Fully Automatic? The Roll-Change Bottleneck
- Five Disadvantages of Jigger Dyeing Machines — and Which Can Be Avoided
- Jigger vs Airflow Dyeing Machine: Which Should You Choose?
- Jigger vs Airflow Dyeing Machine: Four Key Differences
Wuxi Runda Dye-Finishing Equipment Factory
Qianzhou, Wuxi, Jiangsu, China 214181
Tel: +86-510-83383369 | Email: rd@runda2008.com | www.runda2008.com
Established 2004 | USCC 913202067573212793